Background: The Gopher FITStep Pro (GFSP) is a commercially available objective physical activity monitor that records steps taken and moderate-to-vigorous physical activity (MVPA).

Objective: The purpose of this study was to evaluate the accuracy of the GFSP for measuring steps taken in a guided walking condition and MVPA during planned fitness activities.

Method: University-aged participants (N = 35, Mage = 20) wore two GFSP (right and left side) pedometers and one ActiGraph GT3X+ accelerometer during both conditions.

Results: Paired samples t-tests determined that self-step counts in the guided walking condition were not significantly different than the right side GFSP (p = .084) but were significantly different from the left side GFSP (p = .006). Mean absolute percent error (MAPE) was less than 3% between self-step counts with the left (1.9%) and right side GFPS (1.7%). However, MVPA estimates were significantly different between the GT3X+ accelerometer and the left side and right side GFSP (p < .001). High MAPE occurred between the GT3X+ accelerometer with the left (51%) and right side GFSP (41%) in the planned fitness activity condition.

Conclusion: The GFSP may be an appropriate instrument for estimating steps, however users should be cautious when consuming MVPA estimates for educational, research, or health-related purposes.

Keywords: pedometer, accelerometer, validation, physical education

Received: October 1, 2016; Accepted: February 13, 2017; Prepublished online: March 1, 2017; Published: March 31, 2017Show citation

ACS AIP APA ASA Harvard Chicago IEEE ISO690 MLA NLM Turabian Vancouver
Brian, A., & Haegele, J.A. (2017). Gopher FITStep Pro accuracy when measuring steps and moderate-to-vigorous physical activity. Acta Gymnica47(1), 3-10. doi: 10.5507/ag.2017.006.
Download citation

References

  1. Barreira, T. V., Tudor-Locke, C., Champagne, C. M., Broyles, S. T., Johnson, W. D., & Katzmarzyk, P. T. (2013). Comparison of GT3X accelerometer and Yamax pedometer steps/days in a free-living sample of overweight and obese adults. Journal of Physical Activity & Health, 10, 263-270. Go to original source... Go to PubMed...
  2. Bland, J. M., & Altman, D. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 327, 307-310. Go to original source...
  3. Brusseau, T. A., & Burns, R. D. (2013). Pedometer-determined physical activity of youth while attending school: A review. Sport Science Review, 22, 329-342. Go to original source...
  4. Brusseau, T. A., & Burns, R. D. (2015). Step count and MVPA compendium for middle school physical education activities. Journal of Physical Education and Sport, 15, 646-650.
  5. Brusseau, T., Kulinna, P. H., Tudor-Locke, C., Ferry, M., van der Mars, H., & Darst, P. W. (2011). Pedometer-determined segmented physical activity patterns of fourth- and fifth-grade children. Journal of Physical Activity & Health, 8, 279-286. Go to original source... Go to PubMed...
  6. Clemes, S. A., & Biddle, S. J. H. (2013). The use of pedometers for monitoring physical activity in children and adolescents: Measurement considerations. Journal of Physical Activity & Health, 10, 249-262. Go to original source... Go to PubMed...
  7. Crouter, S. E., Schenieder, P. L., & Bassett, D. R. (2005). Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults. Medicine & Science in Sports & Exercise, 37, 1673-1679. Go to original source...
  8. Elies, S. (2015). Performance analysis of commercial accelerometers: A parameter review. Sensors & Transducers, 193, 179-190.
  9. Freedson, J., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine & Science in Sport & Exercise, 30, 777-781. Go to original source...
  10. Gatti, A., Stratford, P., Brenneman, E., & Maly, M. (2015). GT3X+ accelerometer placement affects the reliability of step-counts measured during running and pedal-revolution counts measured during bicycling. Journal of Sports Sciences, 33, 1-8.
  11. Gopher. (2015). FITStep Pro uploadable pedometers. Retrieved from http://www.gophersport.com/pe/teacher-resources-pedometers/FITStep-pro-uploadable-pedometers?ca=1809
  12. Hänggi, J. M., Phillips, L. R., & Rowlands, A. V. (2013). Validation of the GT3X ActiGraph in children andcomparison with the GT1M ActiGraph. Journal of Science and Medicine in Sport, 16, 40-44. Go to original source... Go to PubMed...
  13. Hasson, R. E., Haller, J., Pober, D. M., Staudenmayer, J., & Freedson, P. S. (2009). Validity of the Omron HJ-112 pedometer during treadmill walking. Medicine & Science in Sport & Exercise, 41, 805-809. Go to original source...
  14. Holbrook, E., Barreira, T. V., & Kang, M. (2009). Validity and reliability of Omron pedometers for prescribed and self-paced walking. Medicine & Science in Sports & Exercise, 41, 670. Go to original source...
  15. Jarrett, H., Fitzgerald, L., & Routen, A. C. (2015). Interinstrument reliability of the ActiGraph GT3X+ ambulatory activity monitor during free-living conditions in adults. Journal of Physical Activity & Health, 12, 382-387. Go to original source... Go to PubMed...
  16. Kang, M., Marshall, S. J., Barreira, T. V., & Lee, J.-O. (2009). Effect of pedometer-based physical activity interventions: A meta-analysis. Research Quarterly for Exercise and Sport, 80, 648-655. Go to original source...
  17. Kurti, A. N., & Dallery, J. (2013). Internet-based contingency management increases walking in sedentary adults. Journal of Applied Behavior Analysis, 46, 568-581. Go to original source... Go to PubMed...
  18. Lee, J. A., Williams, S. M., Brown, D. D., & Laurson, K. R. (2015). Concurrent validation of the Actigraph gt3x+, Polar Active accelerometer, Omron HJ-720 and Yamax Digiwalker SW-701 pedometer step counts in lab-based free living settings. Journal of Sports Sciences, 33, 991-1000. Go to original source... Go to PubMed...
  19. Metzler, M., McKenzie, T. L., van der Mars, H., Barrett-Williams, S. L., & Ellis, R. (2013). Health optimizing physical education: A new curriculum for school programs - Part 1: Establishing the need and describing the model. Journal of Physical Education, Recreation, & Dance, 84(4), 23-28. Go to original source...
  20. Morgan, C. F., Pangrazi, R. P., & Beighle, A. (2003). Using pedometers to promote physical activity in physical education. Journal of Physical Education, Recreation, & Dance, 74(7), 33-38. Go to original source...
  21. O'Neil, M. E., Fragala-Pinkham, M. A., Forman, J. L., & Trost, S. G. (2014). Measuring reliability and validity ofthe ActiGraph GT3X accelerometer for children with cerebral palsy: A feasibility study. Journal of Pediatric Rehabilitation Medicine, 7, 233-240.
  22. Pangrazi, R. P., Beighle, A., & Sidman, C. L. (2003). Pedometer power: 67 lessons for K-12. Champaign, IL: Human Kinetics.
  23. Pitchford, E. A., & Yun, J. (2011). Pedometer variance in adults with Down syndrome during free walking: A generalizability study. Journal of Physical Activity & Health, 8, 1143-1151. Go to original source... Go to PubMed...
  24. Schneider, P. L., Crouter, S. E., Lukajic, O., & Bassett, D. R. (2003). Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Medicine & Science in Sports & Exercise, 35, 1779-1784. Go to original source...
  25. Steeves, J. A., Tyo, B. M., Connolly, C. P., Gregory, D. A., Stark, N. A., & Bassett, D. R. (2011). Validity and reliability of the Omron HJ-303 tri-axial accelerometer-based pedometer. Journal of Physical Activity & Health, 8, 1014-1020. Go to original source... Go to PubMed...
  26. Trapp, G. S. A., Giles-Corti, B., Bulsara, M., Christian, H. E., Timperio, A. F., McCormack, G. R., & Villanueva, K. (2013). Measurement of children's physical activity using a pedometer with a built-in memory. Journal of Science and Medicine in Sport, 16, 222-226. Go to original source... Go to PubMed...
  27. Tudor-Locke, C., & Myers, A. M. (2001). Methodological considerations for researchers and practitioners using pedometers to measure physical (ambulatory) activity. Research Quarterly for Exercise and Sport, 72, 1-12. Go to original source... Go to PubMed...
  28. Wetten, A. A., Batterham, M., Tan, S. Y., & Tapsell, L. (2014). Relative validity of 3 accelerometer models for estimating energy expenditure during light activity. Journal of Physical Activity & Health, 11, 638-647. Go to original source... Go to PubMed...
  29. Yang, C.-C., & Hsu, Y.-L. (2010). A review of accelerometry-based wearable motion detectors for physical activity monitoring. Sensors, 10, 7772-7788. Go to original source... Go to PubMed...

This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.